Unitronic LAN 600 S / UTP Cat.7 Y Flex 4x2x26/7 AWG - per meter
Flexible data cable for transmission of digital and analog signals up to 600 MHz. The cable is mainly designed for the use in the area of the workstation. According to TIA/EIA-568-B, ISO/IEC 11801 2nd edition, EN 50173, EN 50288-4-2, IEC 61156-6.
For application in LANs like IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, 10GBase-T; FDDI; ISDN; ATM; Cable sharing.
- Roll 205m Cat7
Article | |
Brand | LAPP |
Product Code | DB2170144EN2 |
Design | |
Conductor | bare copper AWG 26/7, stranded wire |
Insulation | Skin-Foam-Skin PE, ca. 1.03 mm outer Ø |
Core identification code | pair 1: white-blue/blue, pair 2: white-orange/orange, pair 3: white-green/green, pair 4: white-brown/brown |
Stranding | cores stranded to pair, 4 pairs stranded to bundle |
Screen | pair screening: plastic laminated aluminium foil braid of copper wire, tinned wire ca. 0,10 mm |
Outer sheath | PVC / grey, similar RAL 7035 / outer Ø: ca. 6.2 mm |
Electrical properties at 20°C | |
Insulation resistance | in. 2 GΩ x km |
Mutual capacitance | nom. 45 nF/km |
Characteristic impedance | om. 100 Ω acc. to IEC 61156-6 |
Velocity of propagation | 0.78 c |
Signal propagation time | ≤ 450 ns/100 m |
Delay | ≤ 10 ns/100 m |
Screening attenuation | > 60 dB |
Peak operating voltage | 100 V (not for power purposes) |
Test voltage | Core/Core: 700 V - Core/Screen: 700 V |
Mechanical and thermal properties | |
Minimum bending radius | during installation: 8 x cable Ø / fixed: 4 x cable Ø |
Temperature range | during installation: 0˚ C up to +50˚ C / fixed: -20˚ C up to +60˚ C |
Flammability | flame retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 |
General requirements | These cables are conform to the EU-Directive 2011/65/EU (RoHS, Restriction of the use of certain hazardous substances) and the LV-Directive 2014/35/EU (Low voltage Directive). |
Environmental information | These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS). |
General | |
Loop resistance | ax. 29 Ω/100 m |